I have filled two cooling systems and placed them into the prototype in place of the original heatsinks. I still use the old duct that doesn't match exactly with the new power supply walls and new condensers, so it leaked air, reducing the airflow that went through the fins.

Testing was done in the "worst-case-scenario" conditions, with the outside air temperature 25-26C (77-79F) and two cpuburn processes running. CPU temperatures (measured by the motherboard sensors) were 64-66C while running cpuburn, 56-57C when idle. Likely just making a better duct will drop them further.

350W power supply worked without problems.